Research Article | Volume : 1 Issue : 7, September 2011

High performance thin layer chromatographic method for estimation of deflazacort in tablet

Patel Satish A Patel Natvarlal J.   

Open Access   

Abstract

A simple and sensitive high performance thin layer chromatography (HPTLC) method has been developed for the quantitative estimation of deflazacort in its single component tablet formulation (30 mg). Deflazacort was chromatographed on silica gel 60 F254 TLC plate using benzene: methanol: glacial acetic acid (7.5:2.0:0.5, v/v/v) as mobile phase. Deflazacort showed Rf value of 0.60 + 0.02 and scanned at 243 nm using a camag TLC scanner 3. The method was validated in terms of linearity (100 – 800 ng/spot), precision (intra-day variation, 0.335 to 1.203% and inter-day variation, 0.231 to 1.471%), accuracy (98.87 to 99.77%) and specificity. The limit of detection and limit of quantification for deflazacort were found to be 25.97 ng/spot and 85.70 ng/spot, respectively. The developed method was successfully used for the assay of deflazacort tablet formulation. The method was found to be simple, sensitive, specific, accurate and precise and can be used for the routine quality control testing of deflazacort in tablet dosage form.


Keyword:     Deflazacort HPTLC validation tablet.


Copyright:The Author(s). This is an open access article distributed under the Creative Commons Attribution Non-Commercial License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

HTML Full Text

Reference

Article Metrics
374 Views 17 Downloads 391 Total

Year

Month

Related Search

By author names